| Milestone dates |
|
pre-engineering contract
|
August 2003 |
Start engineering and testing
|
January 2004 |
Engineering and design approved
|
August 2004 |
Start production wings |
February 2005 |
Last transport last wing parts |
July 2005 |
All five wings installed |
November 2005 |
|
| Material composition roofs |
: |
Sandwich with a core material of non-combustible PIR foam
and a stressed skin of glass fibre reinforced polyester.
The sandwich has an integrated web of inserts and ribs
|
Glass facades Library and Great Hall
|
Gross glass surface |
: |
650 m2
|
| Façade system |
: |
Point fixed structural glazing to the roof supporting columns
|
| Fire protection steel |
: |
Steel columns are filled with concrete and protected with
fire intumescent paint giving one hour fire-resistance.
|
| Fire protection roofs |
: |
Roofs are tested following EN 13823:2002 “Single burning
Item and 11925-2:2002 “Ignitability” |
| Fire classification |
: |
The roof system is classified following EN 13501-1:2002 clause
8.2 as: C-s2,d0. This classification is valid for the end use
conditions when horizontally mounted as a roof construction
or vertically as a wall |
| Glass composition |
: |
Insulation glass out of fully tempered and heatsoak tested
panels with sun shielding low E coating and silkscreen printed
dots. Glass on floor level also consisting laminated safety
glass. |